{"id":2903,"date":"1993-09-15T17:33:27","date_gmt":"1993-09-15T22:33:27","guid":{"rendered":"https:\/\/kermitmurray.com\/research\/?p=2903"},"modified":"2024-02-20T09:39:00","modified_gmt":"2024-02-20T15:39:00","slug":"liquid-sample-introduction-for-matrix-assisted-laser-desorption-ionization","status":"publish","type":"post","link":"https:\/\/kermitmurray.com\/research\/1993\/09\/liquid-sample-introduction-for-matrix-assisted-laser-desorption-ionization\/","title":{"rendered":"Liquid Sample Introduction for Matrix-Assisted Laser Desorption Ionization"},"content":{"rendered":"\n<p>K.K. Murray, D.H. Russell, Liquid Sample Introduction for Matrix-Assisted Laser Desorption Ionization, Anal. Chem., 65 (1993) 2534-2537; <a href=\"http:\/\/10.1021\/ac00066a023\">http:\/\/10.1021\/<\/a><a href=\"http:\/\/dx.doi.org\/10.1021\/ac00066a023\">ac00066a023<\/a>.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Abstract<\/h4>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignright is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/AMALDI-JASMS-Low-Quality.jpg\" alt=\"\" class=\"wp-image-937\" width=\"450\" height=\"505\" srcset=\"https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/AMALDI-JASMS-Low-Quality.jpg 600w, https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/AMALDI-JASMS-Low-Quality-267x300.jpg 267w\" sizes=\"auto, (max-width: 450px) 100vw, 450px\" \/><figcaption>Aerosol MALDI apparatus at Texas A&#038;M University<\/figcaption><\/figure><\/div>\n\n\n\n<p>In this paper initial results are presented for a new liquid introduction method for a mass spectrometer based on the application of MALDI to aerosols. Details of the method will be presented in future publications. Aerosols are formed using a continuous pneumatic aerosol generator from an acidified methanol solution containing the matrix and analyte. The solvent is removed by passing the aerosol through a heated tube to form a collimated beam of dried particles. Ions are formed by irradiating the aerosol with pulsed UV radiation in the source region of a linear TOF MS. The advantages of the aerosol MALDI TOF method are (1) liquid flow capacity of 0.5 mL\/min, (2) rapid acquisition of the entire mass spectrum, and (3) ionization of large peptides and proteins. In this paper, the aerosol MALDI mass spectra of gramicidin S and lysozyme (chicken egg white) are presented. Flow injection mass spectra of gramicidin S are presented to demonstrate the feasibility of coupling aerosol MALDI with HPLC.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"697\" src=\"https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/KKM-1993s-1024x697.jpg\" alt=\"Kermit Murray at Texas A&amp;M University in 1993\" class=\"wp-image-918\" srcset=\"https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/KKM-1993s-1024x697.jpg 1024w, https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/KKM-1993s-300x204.jpg 300w, https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/KKM-1993s.jpg 1194w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption>Kermit Murray at Texas A&#038;M University in 1993<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/AMALDI-SIde-View-1024x683.jpg\" alt=\"AMALDI side view\" class=\"wp-image-965\" srcset=\"https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/AMALDI-SIde-View-1024x683.jpg 1024w, https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/AMALDI-SIde-View-300x200.jpg 300w, https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/AMALDI-SIde-View.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption>Texas A&#038;M Aerosol MALDI instrument side view<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/TAMU-AMALDI-1992-Flight-Tube-1024x683.jpg\" alt=\"TAMU AMALDI Mass Spectrometer 1992\" class=\"wp-image-963\" srcset=\"https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/TAMU-AMALDI-1992-Flight-Tube-1024x683.jpg 1024w, https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/TAMU-AMALDI-1992-Flight-Tube-300x200.jpg 300w, https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/TAMU-AMALDI-1992-Flight-Tube.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption>Aerosol MALDI instrument at Texas A&#038;M University, showing the flight tube  (right) and ion source (left).<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"675\" src=\"https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/AMALDI-1992-1024x675.jpg\" alt=\"AMALDI Instrument at Texas A&amp;M\" class=\"wp-image-959\" srcset=\"https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/AMALDI-1992-1024x675.jpg 1024w, https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/AMALDI-1992-300x198.jpg 300w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption>Aerosol MALDI Instrument at Texas A&#038;M University, 1992.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/Roots-Blower-TAMU-1992-683x1024.jpg\" alt=\"TAMU Roots pump\" class=\"wp-image-961\" width=\"683\" height=\"1024\" srcset=\"https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/Roots-Blower-TAMU-1992-683x1024.jpg 683w, https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/Roots-Blower-TAMU-1992-200x300.jpg 200w, https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/07\/Roots-Blower-TAMU-1992.jpg 1200w\" sizes=\"auto, (max-width: 683px) 100vw, 683px\" \/><figcaption>Roots blower and backing pump at Texas A&#038;M University, 1992<\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>K.K. Murray, D.H. Russell, Liquid Sample Introduction for Matrix-Assisted Laser Desorption Ionization, Anal. Chem., 65 (1993) 2534-2537; http:\/\/10.1021\/ac00066a023. Abstract In this paper initial results are presented for a new liquid introduction method for a mass spectrometer based on the application of MALDI to aerosols. Details of the method will be presented in future publications. Aerosols &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/kermitmurray.com\/research\/1993\/09\/liquid-sample-introduction-for-matrix-assisted-laser-desorption-ionization\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Liquid Sample Introduction for Matrix-Assisted Laser Desorption Ionization&#8221;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":937,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[143,144,17,133],"tags":[11],"class_list":["post-2903","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-aerosol","category-aerosol-research-areas","category-instrum","category-tamu","tag-asms","entry"],"_links":{"self":[{"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/posts\/2903","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/comments?post=2903"}],"version-history":[{"count":4,"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/posts\/2903\/revisions"}],"predecessor-version":[{"id":2907,"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/posts\/2903\/revisions\/2907"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/media\/937"}],"wp:attachment":[{"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/media?parent=2903"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/categories?post=2903"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/tags?post=2903"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}