{"id":2128,"date":"2014-10-20T11:50:50","date_gmt":"2014-10-20T16:50:50","guid":{"rendered":"https:\/\/kermitmurray.com\/murray\/?p=2128"},"modified":"2024-02-20T09:39:00","modified_gmt":"2024-02-20T15:39:00","slug":"2128","status":"publish","type":"post","link":"https:\/\/kermitmurray.com\/research\/2014\/10\/2128\/","title":{"rendered":"Tip-enhanced laser ablation sample transfer for biomolecule mass spectrometry"},"content":{"rendered":"\n<div class=\"wp-block-caxton-grid relative\"><div class=\"absolute absolute--fill\"><div class=\"cover bg-center absolute absolute--fill\" style=\"background-color:;background-image:linear-gradient( );\"><\/div><div class=\"absolute absolute--fill\" style=\"background-color:;background-image:linear-gradient( );opacity:1;\"><\/div><\/div><div class=\"relative caxton-columns caxton-grid-block\" style=\"padding-top:0;padding-left:0;padding-bottom:0;padding-right:0;grid-template-columns:repeat(12, 1fr)\" data-tablet-css=\"padding-left:em;padding-right:em;\" data-mobile-css=\"padding-left:em;padding-right:em;\">\n<div class=\"wp-block-caxton-section relative\" style=\"grid-area:span 1\/span 12\"><div class=\"absolute absolute--fill\"><div class=\"cover bg-center absolute absolute--fill\" style=\"background-color:;background-image:linear-gradient( );\"><\/div><div class=\"absolute absolute--fill\" style=\"background-color:;background-image:linear-gradient( );opacity:1;\"><\/div><\/div><div class=\"relative caxton-section-block\" style=\"padding-top:5px;padding-left:5px;padding-bottom:5px;padding-right:5px\" data-mobile-css=\"padding-left:1em;padding-right:1em;\" data-tablet-css=\"padding-left:1em;padding-right:1em;\">\n<p>S. Ghorai, C.A. Seneviratne, K.K. Murray, &#8220;Tip-enhanced laser ablation sample transfer for biomolecule mass spectrometry,&#8221;  <em>J. Am. Soc. Mass Spectrom.<\/em><strong>26<\/strong> (2015) 63\u201370. doi:<a href=\"http:\/\/doi.org\/10.1007\/s13361-014-1005-x\">10.1007\/s13361-014-1005-x<\/a>.<\/p>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-caxton-grid relative\"><div class=\"absolute absolute--fill\"><div class=\"cover bg-center absolute absolute--fill\" style=\"background-color:;background-image:linear-gradient( );\"><\/div><div class=\"absolute absolute--fill\" style=\"background-color:;background-image:linear-gradient( );opacity:1;\"><\/div><\/div><div class=\"relative caxton-columns caxton-grid-block\" style=\"padding-top:0;padding-left:0;padding-bottom:0;padding-right:0;grid-template-columns:repeat(12, 1fr)\" data-tablet-css=\"padding-left:em;padding-right:em;\" data-mobile-css=\"padding-left:em;padding-right:em;\">\n<div class=\"wp-block-caxton-section relative\" style=\"grid-area:span 1\/span 8\"><div class=\"absolute absolute--fill\"><div class=\"cover bg-center absolute absolute--fill\" style=\"background-color:;background-image:linear-gradient( );\"><\/div><div class=\"absolute absolute--fill\" style=\"background-color:;background-image:linear-gradient( );opacity:1;\"><\/div><\/div><div class=\"relative caxton-section-block\" style=\"padding-top:5px;padding-left:5px;padding-bottom:5px;padding-right:5px\" data-mobile-css=\"padding-left:1em;padding-right:1em;\" data-tablet-css=\"padding-left:1em;padding-right:1em;\">\n<p><em>Abstract<\/em>: Atomic force microscope (AFM) tip-enhanced laser ablation was used to transfer molecules from thin films to a suspended silver wire for off-line mass spectrometry using laser desorption ionization (LDI) and matrix-assisted laser desorption ionization (MALDI). An AFM with a 30 nm radius gold-coated silicon tip was used to image the sample and to hold the tip 15 nm from the surface for material removal using a 355 nm Nd:YAG laser. The ablated material was captured on a silver wire that was held 300 \u03bcm vertically and 100 \u03bcm horizontally from the tip. For the small molecules anthracene and rhodamine 6G, the wire was cut and affixed to a metal target using double-sided conductive tape and analyzed by LDI using a commercial laser desorption time-of-flight mass spectrometer. Approximately 100 fg of material was ablated from each of the 1 \u03bcm ablation spots and transferred with approximately 3% efficiency. For larger polypeptide molecules angiotensin II and bovine insulin, the captured material was dissolved in saturated matrix solution and deposited on a target for MALDI analysis.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-caxton-section relative\" style=\"grid-area:span 1\/span 4\"><div class=\"absolute absolute--fill\"><div class=\"cover bg-center absolute absolute--fill\" style=\"background-color:;background-image:linear-gradient( );\"><\/div><div class=\"absolute absolute--fill\" style=\"background-color:;background-image:linear-gradient( );opacity:1;\"><\/div><\/div><div class=\"relative caxton-section-block\" style=\"padding-top:5px;padding-left:5px;padding-bottom:5px;padding-right:5px\" data-mobile-css=\"padding-left:1em;padding-right:1em;\" data-tablet-css=\"padding-left:1em;padding-right:1em;\">\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"756\" height=\"825\" src=\"https:\/\/kermitmurray.com\/murray\/wp-content\/uploads\/2015\/06\/JASMS-TOC_MS.jpg\" alt=\"\" class=\"wp-image-696\" srcset=\"https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/06\/JASMS-TOC_MS.jpg 756w, https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/06\/JASMS-TOC_MS-275x300.jpg 275w\" sizes=\"auto, (max-width: 756px) 100vw, 756px\" \/><figcaption>AFM image of ablation crater of an insulin thin film and MALDI mass spectrum of the collected material<\/figcaption><\/figure>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-caxton-grid relative\"><div class=\"absolute absolute--fill\"><div class=\"cover bg-center absolute absolute--fill\" style=\"background-color:;background-image:linear-gradient( );\"><\/div><div class=\"absolute absolute--fill\" style=\"background-color:;background-image:linear-gradient( );opacity:1;\"><\/div><\/div><div class=\"relative caxton-columns caxton-grid-block\" style=\"padding-top:0;padding-left:0;padding-bottom:0;padding-right:0;grid-template-columns:repeat(12, 1fr)\" data-tablet-css=\"padding-left:em;padding-right:em;\" data-mobile-css=\"padding-left:em;padding-right:em;\">\n<div class=\"wp-block-caxton-section relative\" style=\"grid-area:span 1\/span 6\"><div class=\"absolute absolute--fill\"><div class=\"cover bg-center absolute absolute--fill\" style=\"background-color:;background-image:linear-gradient( );\"><\/div><div class=\"absolute absolute--fill\" style=\"background-color:;background-image:linear-gradient( );opacity:1;\"><\/div><\/div><div class=\"relative caxton-section-block\" style=\"padding-top:5px;padding-left:5px;padding-bottom:5px;padding-right:5px\" data-mobile-css=\"padding-left:1em;padding-right:1em;\" data-tablet-css=\"padding-left:1em;padding-right:1em;\">\n<div class=\"wp-block-image\"><figure class=\"alignleft\"><img loading=\"lazy\" decoding=\"async\" width=\"471\" height=\"540\" src=\"https:\/\/kermitmurray.com\/murray\/wp-content\/uploads\/2015\/06\/AFM-TELA-Setup.jpg\" alt=\"\" class=\"wp-image-698\" srcset=\"https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/06\/AFM-TELA-Setup.jpg 471w, https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/06\/AFM-TELA-Setup-262x300.jpg 262w\" sizes=\"auto, (max-width: 471px) 100vw, 471px\" \/><figcaption>Atomic force microscope with pulsed laser ablation and sample capture<\/figcaption><\/figure><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-caxton-section relative\" style=\"grid-area:span 1\/span 6\"><div class=\"absolute absolute--fill\"><div class=\"cover bg-center absolute absolute--fill\" style=\"background-color:;background-image:linear-gradient( );\"><\/div><div class=\"absolute absolute--fill\" style=\"background-color:;background-image:linear-gradient( );opacity:1;\"><\/div><\/div><div class=\"relative caxton-section-block\" style=\"padding-top:5px;padding-left:5px;padding-bottom:5px;padding-right:5px\" data-mobile-css=\"padding-left:1em;padding-right:1em;\" data-tablet-css=\"padding-left:1em;padding-right:1em;\">\n<div class=\"wp-block-image\"><figure class=\"alignleft\"><img loading=\"lazy\" decoding=\"async\" width=\"816\" height=\"510\" src=\"https:\/\/kermitmurray.com\/murray\/wp-content\/uploads\/2015\/06\/AFM-Featured.jpg\" alt=\"\" class=\"wp-image-693\" srcset=\"https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/06\/AFM-Featured.jpg 816w, https:\/\/kermitmurray.com\/research\/wp-content\/uploads\/2015\/06\/AFM-Featured-300x188.jpg 300w\" sizes=\"auto, (max-width: 816px) 100vw, 816px\" \/><figcaption>Atomic force microscope stage with capture wire for tip enhanced laser ablation<\/figcaption><\/figure><\/div>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":693,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[134,5,80],"tags":[11,135,77],"class_list":["post-2128","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-lsu","category-publication","category-tela","tag-asms","tag-lsu","tag-publication","entry"],"_links":{"self":[{"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/posts\/2128","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/comments?post=2128"}],"version-history":[{"count":3,"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/posts\/2128\/revisions"}],"predecessor-version":[{"id":2131,"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/posts\/2128\/revisions\/2131"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/media\/693"}],"wp:attachment":[{"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/media?parent=2128"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/categories?post=2128"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kermitmurray.com\/research\/wp-json\/wp\/v2\/tags?post=2128"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}