Multiple reaction monitoring: Difference between revisions

From Mass Spec Terms
No edit summary
No edit summary
Line 1: Line 1:
{{Rev6|
{{Final|acronym=MRM
Multiple reaction monitoring (MRM)
|def=Application of [[selected reaction monitoring]] to multiple [[product ion]]s from one or more [[precursor ion]]s.
:Note: This term should not be confused with [[consecutive reaction monitoring]], which involves the serial application of three or more stages of selected reaction monitoring.
|rel=
|ref=P. Roepstorff, J. Fohlman. Biomed. Mass Spectrom. 11, 601 (1984).


The application of selected reaction monitoring to multiple product ions from one or more precursor ions. This term should not be confused with consecutive reaction monitoring, which involves the serial application of three or more stages of selected reaction monitoring.
From [235].
}}
{{Rev5|
See [[selected reaction monitoring]] (SRM).
|
}}
{{jchrom|
The application of [[selected reaction monitoring]] to multiple product ions from one or more precursor ions]. This term should not be confused with [[consecutive reaction monitoring]], which involves the serial application of three or more stages of selected reaction monitoring.
|
#D. Zakett, R.G.A. Flynn, R.G. Cooks, J. Phys. Chem. 82 (1978) 2359.
}}
}}
{{asms|
'''Another reader's opinion''':  Please make it clear in the definition of terms that "MRM" is not the correct term for SRM.  I am frustrated by manufacturers that invent their own terms.
}}
{{incorrect|
Page 33:  confusion due to possible confusion between multiple stages of MS and multiple (parallel) reactions}}
{{ProblemTerm}}
==Related term==
*[[Selected reaction monitoring]]
*[[Multiple peak scanning]]
==External links==
*[http://www3.interscience.wiley.com/journal/122221198/abstract How specific is my SRM?: The issue of precursor and product ion redundancy]


[[Category:Reactions]]
[[Category:Reactions]]
{{DEFAULTSORT:Multiple Reaction Monitoring}}
{{DEFAULTSORT:Multiple Reaction Monitoring}}

Revision as of 14:03, 7 June 2013

IUPAC RECOMMENDATIONS 2013
Multiple reaction monitoring MRM
Application of selected reaction monitoring to multiple product ions from one or more precursor ions.
Note: This term should not be confused with consecutive reaction monitoring, which involves the serial application of three or more stages of selected reaction monitoring.
Related Term(s):
Reference(s):

P. Roepstorff, J. Fohlman. Biomed. Mass Spectrom. 11, 601 (1984).

From Definitions of Terms Relating to Mass Spectrometry (IUPAC Recommendations 2013); DOI: 10.1351/PAC-REC-06-04-06 © IUPAC 2013.

Index of Recommended Terms